Probes & Sensors

Get in touch
Wood MoistureStructural Moisture
12 Measuring instruments compatible2 Usecases
M 20
min.4 to max.100 % (dry mass)
min.31 to max.41 % water content

Ranges depend on connected measuring instrument

min.0 to max.80 digits
min.0,3 to max.42.2 wt.-%
min.0,3 to max.12 CM-%

Ranges depend on connected measuring instrument

Wood Moisture
11 Measuring instruments compatible
M 20-HW 200
Needs a carrier system
min.4 to max.100 % (dry mass)
min.31 to max.41 % water content

Ranges depend on connected measuring instrument

Wood Moisture
11 Measuring instruments compatible
M 20-HW 300
Needs a carrier system
min.4 to max.100 % (dry mass)
min.31 to max.41 % water content

Ranges depend on connected measuring instrument

Wood Moisture
11 Measuring instruments compatible
M 20-DS 16
Needs a carrier system
min.4 to max.100 % (dry mass)
min.31 to max.41 % water content

Ranges depend on connected measuring instrument

Wood Moisture
2 Measuring instruments compatible
M 20-DS 16-i
Needs a carrier system
min.4 to max.100 % (dry mass)

Ranges depend on connected measuring instrument

Wood MoistureStructural Moisture
12 Measuring instruments compatible2 Usecases
M 20-OF 15
Needs a carrier system
min.4 to max.100 % (dry mass)
min.31 to max.41 % water content

Ranges depend on connected measuring instrument

min.0 to max.80 digits
min.0,3 to max.42.2 wt.-%
min.0,3 to max.12 CM-%

Ranges depend on connected measuring instrument

Wood Moisture
11 Measuring instruments compatible
M 18
min.4 to max.100 % (dry mass)
min.31 to max.41 % water content

Ranges depend on connected measuring instrument

Wood Moisture
2 Measuring instruments compatible2 Usecases
M 19
min.4 to max.100 % (dry mass)

Ranges depend on connected measuring instrument

Structural Moisture
6 Measuring instruments compatible
M 6
min.0 to max.80 digits
min.0,3 to max.42.2 wt.-%
min.0,3 to max.12 CM-%

Ranges depend on connected measuring instrument

Structural Moisture
6 Measuring instruments compatible
M 6-150
Needs a carrier system
min.0 to max.80 digits
min.0,3 to max.42.2 wt.-%
min.0,3 to max.12 CM-%

Ranges depend on connected measuring instrument

Structural Moisture
6 Measuring instruments compatible
M 6-250
Needs a carrier system
min.0 to max.80 digits
min.0,3 to max.42.2 wt.-%
min.0,3 to max.12 CM-%

Ranges depend on connected measuring instrument

Structural Moisture
6 Measuring instruments compatible2 Usecases
M 6-Bi 200
Needs a carrier system
min.0 to max.80 digits
min.0,3 to max.42.2 wt.-%
min.0,3 to max.12 CM-%

Ranges depend on connected measuring instrument

Structural Moisture
6 Measuring instruments compatible2 Usecases
M 6-Bi 300
Needs a carrier system
min.0 to max.80 digits
min.0,3 to max.42.2 wt.-%
min.0,3 to max.12 CM-%

Ranges depend on connected measuring instrument

Structural Moisture
6 Measuring instruments compatible2 Usecases
M 20-Bi 200
Needs a carrier system
min.0 to max.80 digits
min.0,3 to max.42.2 wt.-%
min.0,3 to max.12 CM-%

Ranges depend on connected measuring instrument

Structural Moisture
6 Measuring instruments compatible2 Usecases
M 20-Bi 300
Needs a carrier system
min.0 to max.80 digits
min.0,3 to max.42.2 wt.-%
min.0,3 to max.12 CM-%

Ranges depend on connected measuring instrument

Structural Moisture
6 Measuring instruments compatible
M 21-100
min.0 to max.80 digits
min.0,3 to max.42.2 wt.-%
min.0,3 to max.12 CM-%

Ranges depend on connected measuring instrument

Structural Moisture
6 Measuring instruments compatible
M 21-250
min.0 to max.80 digits
min.0,3 to max.42.2 wt.-%
min.0,3 to max.12 CM-%

Ranges depend on connected measuring instrument

Structural Moisture
6 Measuring instruments compatible2 Usecases
M 25-100
min.0 to max.80 digits
min.0,3 to max.42.2 wt.-%
min.0,3 to max.12 CM-%

Ranges depend on connected measuring instrument

Structural Moisture
6 Measuring instruments compatible2 Usecases
M 25-300
min.0 to max.80 digits
min.0,3 to max.42.2 wt.-%
min.0,3 to max.12 CM-%

Ranges depend on connected measuring instrument

Structural Moisture
2 Measuring instruments compatible
Compact Bi 175
min.0.4 to max.6 wt.-%

Ranges depend on connected measuring instrument

Structural Moisture
2 Measuring instruments compatible
Compact HW 175
min.0.4 to max.6 wt.-%

Ranges depend on connected measuring instrument

Structural Moisture
4 Measuring instruments compatible2 Usecases
B 50
0 to 199 digits
0.3 to 8.5 wt.-%
0.3 to 6.5 CM-%
Structural Moisture
4 Measuring instruments compatible2 Usecases
B 60
0 to 199 digits
0.3 to 8.5 wt.-%
0.3 to 6.5 CM-%
Structural Moisture
4 Measuring instruments compatible
LB 71
0 to 199 digits
0.3 to 8.5 wt.-%
0.3 to 6.5 CM-%
Structural Moisture
3 Measuring instruments compatible2 Usecases
B 55 BL
0 to 199 digits
0.3 to 8.5 wt.-%
0.3 to 6.5 CM-%
Air HumidityAir Temperature
3 Measuring instruments compatible
RF-T 28 EL
0 to 100 % R.H.
±1.8 (10 to 85 % R.H.) Sensor Accuracy
-10 to 70 °C
±0.75 (-10 to 55 °C) Sensor Accuracy
Air HumidityAir Temperature
3 Measuring instruments compatible
RH-T 37 EL 160
0 to 100 % R.H.
±1.8 (10 to 90 % R.H.) Sensor Accuracy
-20 to 70 °C
±0.5 (-10 to 70 °C) Sensor Accuracy
Air HumidityAir Temperature
3 Measuring instruments compatible
RH-T 37 EL 320
0 to 100 % R.H.
±1.8 (10 to 90 % R.H.) Sensor Accuracy
-20 to 70 °C
±0.5 (-10 to 70 °C) Sensor Accuracy
Air HumidityAir Temperature
3 Measuring instruments compatible
RH-T 37 EL flex 250
0 to 100 % R.H.
±1.8 (10 to 90 % R.H.) Sensor Accuracy
-20 to 70 °C
±0.5 (-10 to 70 °C) Sensor Accuracy
Air HumidityAir Temperature
3 Measuring instruments compatible
RH-T 37 EL flex 350
0 to 100 % R.H.
±1.8 (10 to 90 % R.H.) Sensor Accuracy
-20 to 70 °C
±0.5 (-10 to 70 °C) Sensor Accuracy
Air HumidityAir TemperatureStructural Moisture
2 Measuring instruments compatible
RH-T 37 BL 160
0 to 100 % R.H.
±1.8 (10 to 90 % R.H.) Sensor Accuracy
-20 to 70 °C
±0.5 (-10 to 70 °C) Sensor Accuracy
Air HumidityAir TemperatureStructural Moisture
2 Measuring instruments compatible
RH-T 37 BL 320
0 to 100 % R.H.
±1.8 (10 to 90 % R.H.) Sensor Accuracy
-20 to 70 °C
±0.5 (-10 to 70 °C) Sensor Accuracy
Air HumidityAir TemperatureStructural Moisture
2 Measuring instruments compatible
RH-T 37 BL flex 250
0 to 100 % R.H.
±1.8 (10 to 90 % R.H.) Sensor Accuracy
-20 to 70 °C
±0.5 (-10 to 70 °C) Sensor Accuracy
Air HumidityAir TemperatureStructural Moisture
2 Measuring instruments compatible
RH-T 37 BL flex 350
0 to 100 % R.H.
±1.8 (10 to 90 % R.H.) Sensor Accuracy
-20 to 70 °C
±0.5 (-10 to 70 °C) Sensor Accuracy
Air TemperatureAir Humidity
4 Measuring instruments compatible
16 K-21
-20 to 80 °C
±0.5 (0 to 60 °C) Sensor Accuracy
0 to 100 % R.H.
±3 (20 to 80 % R.H.) Sensor Accuracy
Air HumidityAir Temperature
4 Measuring instruments compatible
16 K-25
0 to 100 % R.H.
±1.8 (20 to 90 % R.H.) Sensor Accuracy
-20 to 80 °C
±0.2 (10 to 60 °C) Sensor Accuracy
Air HumidityAir Temperature
4 Measuring instruments compatible
16 K-25 P
0 to 100 % R.H.
±1.8 (10 to 90 % R.H.) Sensor Accuracy
-20 to 80 °C
±0.2 (10 to 60 °C) Sensor Accuracy
Air HumidityAir Temperature
4 Measuring instruments compatible
16 K-25 M
0 to 100 % R.H.
±1.8 (10 to 90 % R.H.) Sensor Accuracy
-20 to 80 °C
±0.2 (10 to 60 °C) Sensor Accuracy
Surface Temperature
4 Measuring instruments compatible
IR 40 EL
-20 to 199.9 °C
±0.5 (0 to 60 °C) Sensor Accuracy
Air HumidityAir TemperatureSurface Temperature
2 Measuring instruments compatible
TF-IR BL
0 to 100 % R.H.
±2 (20 to 80 % R.H.) Sensor Accuracy
-20 to 70 °C
±0.5 (-10 to 60 °C) Sensor Accuracy
-40 to 380 °C
±0.5 (0 to 60 °C) Sensor Accuracy
Material Temperature
4 Measuring instruments compatible
FT 2
-20 to 120 °C
Material Temperature
4 Measuring instruments compatible
FT 5
-20 to 120 °C
Material Temperature
4 Measuring instruments compatible
FT 10
-20 to 120 °C
Material Temperature
4 Measuring instruments compatible
FT 20
-20 to 120 °C
Material Temperature
4 Measuring instruments compatible
FT 30
-20 to 120 °C
Air Temperature
4 Measuring instruments compatible
LT 20
-20 to 200 °C
Material Temperature
4 Measuring instruments compatible
ET 10
-50 to 250 °C
Material Temperature
4 Measuring instruments compatible
ET 50
-50 to 300 °C
Surface Temperature
4 Measuring instruments compatible
OT 100
-50 to 250 °C
Surface Temperature
4 Measuring instruments compatible
OTW 90
-50 to 250 °C
Surface Temperature
3 Measuring instruments compatible
OTW 480
-50 to 600 °C
Material Temperature
4 Measuring instruments compatible
TT 30
-50 to 350 °C
Material Temperature
4 Measuring instruments compatible
TT 40
-50 to 350 °C
Material Temperature
3 Measuring instruments compatible
TT 480
-50 to 600 °C
Material Temperature
3 Measuring instruments compatible
TT 600
-50 to 600 °C
Air Speed
2 Measuring instruments compatible
LG-25 BL
-2.5 to 2.5 m/s
Material Temperature
4 Measuring instruments compatible
ET 10 BL
-50 to 250 °C
Surface Temperature
3 Measuring instruments compatible
OT 100 BL
-50 to 250 °C
Material Temperature
3 Measuring instruments compatible
TT 40 BL
-50 to 350 °C

Your question about our products

Stay informed about
GANN products & services