Structural Moisture

Stick-in Electrode Pin Pair
M 20-Bi 200

Ref.Nr. 31004360
Stick-in electrodes for resistance-based moisture measurement of materials hidden beneath another panel or covering
DescriptionUsecases

Description

The stick-in electrode pins M 20-Bi 200 are used for measurement of materials hidden beneath another panel or covering

The pair of electrodes is isolated on the stem.

Measuring ranges

Structural Moisture
The electrode pair can be used with all hydromettes based on the resistance measurement method.
Resistance-based measuring
Resistance-based measuring
Measuring Ranges
min.0 to max.80 digits
min.0,3 to max.42.2 wt.-%
min.0,3 to max.12 CM-%

The actual measuring range depends on the connected measuring instrument.

Show compatible measuring instruments

Specifications

  • The insulation on the stem prevents surface moisture from skewing the measuring result
Length0.200 m0.656 ft (0.200 m)

Carrier SystemNeeds one of these carrier systems

Wood MoistureStructural Moisture
12 Measuring instruments compatible2 Usecases
M 20
min.4 to max.100 % (dry mass)
min.31 to max.41 % water content

Ranges depend on connected measuring instrument

min.0 to max.80 digits
min.0,3 to max.42.2 wt.-%
min.0,3 to max.12 CM-%

Ranges depend on connected measuring instrument

Structural Moisture
6 Measuring instruments compatible
M 6
min.0 to max.80 digits
min.0,3 to max.42.2 wt.-%
min.0,3 to max.12 CM-%

Ranges depend on connected measuring instrument

Compatible instrumentsCan be used with these measuring instruments

Wood MoistureStructural MoistureAir HumidityAir TemperatureSurface TemperatureMaterial TemperatureAir Speed
33 Electrodes selectable
CH 17
4 to 100 % (dry mass)
0 to 199 digits
0,3 to 8,5 wt.-%
0,3 to 6,5 CM-%
0,3 to 25 wt.-%
0,3 to 12 CM-%
0 to 100 % R.H.
±1,8 (10 to 90 % R.H.) Sensor Accuracy
-20 to 80 °C
±0,3 (-10 to 70 °C) Sensor Accuracy
-40 to 380 °C
±0,5 (0 to 60 °C) Sensor Accuracy
-50 to 250 °C
-30 to 170 °C
-2,5 to 2,5 m/s
Structural MoistureWood MoistureSurface TemperatureMaterial Temperature
21 Electrodes selectable
BL E
0.1 to 42.2 wt.-%
0.2 to 9.9 CM-%
0 to 200 digits
5.5 to 58 % (dry mass)
-50 to 250 °C
-50 to 350 °C
Wood MoistureStructural MoistureSurface Temperature
21 Electrodes selectable
HB 30
4 to 30 % (dry mass)
0 to 80 digits
0.5 to 25 wt.-%
0.3 to 12 CM-%
0 to 199 digits
0.3 to 8.5 wt.-%
0.3 to 6.5 CM-%
-20 to 199.9 °C
Wood MoistureStructural MoistureAir TemperatureSurface TemperatureMaterial Temperature
29 Electrodes selectable
HT 85 T
4 to 100 % (dry mass)
0 to 80 digits
0.5 to 25 wt.-%
0.3 to 12 CM-%
-20 to 200 °C
-50 to 250 °C
-50 to 350 °C
Structural MoistureAir HumidityAir TemperatureSurface TemperatureMaterial Temperature
37 Electrodes selectable
UNI 2
0 to 80 digits
0.5 to 25 wt.-%
0.3 to 12 CM-%
0 to 199 digits
0.3 to 8.5 wt.-%
0.3 to 6.5 CM-%
0 to 100 % R.H.
-20 to 200 °C
-20 to 70 °C
-50 to 600 °C
-20 to 199.9 °C
-50 to 600 °C
Wood MoistureStructural MoistureAir HumidityAir TemperatureSurface TemperatureMaterial Temperature
41 Electrodes selectable
RTU 600
4 to 100 % (dry mass)
0 to 80 digits
0.5 to 25 wt.-%
0.3 to 12 CM-%
0 to 199 digits
0.3 to 8.5 wt.-%
0.3 to 6.5 CM-%
0 to 100 % R.H.
-20 to 200 °C
-20 to 70 °C
-50 to 600 °C
-20 to 199.9 °C
-50 to 600 °C

Your question about this product

Stay informed about
GANN products & services