Structural Moisture

Stick-in Electrode Pin Pair
M 6-150

Ref.Nr. 31003706
Extra thin probes for measuring moisture content over expansion joints or through intersecting tile joints 

Description

The Stick-in electrode pins M 6-150 are used for measuring the moisture content in building and insulating materials. Due to the extra thin probes (150 x 3 mm Ø) it is possible to measure over expansion joints or through intersecting tile joints.

Measuring ranges

Structural Moisture
The electrode pair can be used with all hydromettes based on the resistance measurement method.
Resistance-based measuring
Resistance-based measuring
Measuring Ranges
min.0 to max.80 digits
min.0,3 to max.42.2 wt.-%
min.0,3 to max.12 CM-%

The actual measuring range depends on the connected measuring instrument.

Show compatible measuring instruments

Specifications

  • The tips are uninsulated and thus provide a large contact area. This reduces the risk of incorrect measurements and increases the reliability of the measurement results
  • Ø 3 mm
Length0.150 m0.492 ft (0.150 m)

Carrier SystemNeeds one of these carrier systems

Structural Moisture
6 Measuring instruments compatible
M 6
min.0 to max.80 digits
min.0,3 to max.42.2 wt.-%
min.0,3 to max.12 CM-%

Ranges depend on connected measuring instrument

Wood MoistureStructural Moisture
12 Measuring instruments compatible2 Usecases
M 20
min.4 to max.100 % (dry mass)
min.31 to max.41 % water content

Ranges depend on connected measuring instrument

min.0 to max.80 digits
min.0,3 to max.42.2 wt.-%
min.0,3 to max.12 CM-%

Ranges depend on connected measuring instrument

Compatible instrumentsCan be used with these measuring instruments

Wood MoistureStructural MoistureAir HumidityAir TemperatureSurface TemperatureMaterial TemperatureAir Speed
33 Electrodes selectable
CH 17
4 to 100 % (dry mass)
0 to 199 digits
0,3 to 8,5 wt.-%
0,3 to 6,5 CM-%
0,3 to 25 wt.-%
0,3 to 12 CM-%
0 to 100 % R.H.
±1,8 (10 to 90 % R.H.) Sensor Accuracy
-20 to 80 °C
±0,3 (-10 to 70 °C) Sensor Accuracy
-40 to 380 °C
±0,5 (0 to 60 °C) Sensor Accuracy
-50 to 250 °C
-30 to 170 °C
-2,5 to 2,5 m/s
Structural MoistureWood MoistureSurface TemperatureMaterial Temperature
21 Electrodes selectable
BL E
0.1 to 42.2 wt.-%
0.2 to 9.9 CM-%
0 to 200 digits
5.5 to 58 % (dry mass)
-50 to 250 °C
-50 to 350 °C
Wood MoistureStructural MoistureSurface Temperature
21 Electrodes selectable
HB 30
4 to 30 % (dry mass)
0 to 80 digits
0.5 to 25 wt.-%
0.3 to 12 CM-%
0 to 199 digits
0.3 to 8.5 wt.-%
0.3 to 6.5 CM-%
-20 to 199.9 °C
Wood MoistureStructural MoistureAir TemperatureSurface TemperatureMaterial Temperature
29 Electrodes selectable
HT 85 T
4 to 100 % (dry mass)
0 to 80 digits
0.5 to 25 wt.-%
0.3 to 12 CM-%
-20 to 200 °C
-50 to 250 °C
-50 to 350 °C
Structural MoistureAir HumidityAir TemperatureSurface TemperatureMaterial Temperature
37 Electrodes selectable
UNI 2
0 to 80 digits
0.5 to 25 wt.-%
0.3 to 12 CM-%
0 to 199 digits
0.3 to 8.5 wt.-%
0.3 to 6.5 CM-%
0 to 100 % R.H.
-20 to 200 °C
-20 to 70 °C
-50 to 600 °C
-20 to 199.9 °C
-50 to 600 °C
Wood MoistureStructural MoistureAir HumidityAir TemperatureSurface TemperatureMaterial Temperature
41 Electrodes selectable
RTU 600
4 to 100 % (dry mass)
0 to 80 digits
0.5 to 25 wt.-%
0.3 to 12 CM-%
0 to 199 digits
0.3 to 8.5 wt.-%
0.3 to 6.5 CM-%
0 to 100 % R.H.
-20 to 200 °C
-20 to 70 °C
-50 to 600 °C
-20 to 199.9 °C
-50 to 600 °C

Your question about this product

Stay informed about