Probes & Sensors
Structural Moisture

Get in touch
Wood MoistureStructural Moisture
12 Measuring instruments compatible2 Usecases
M 20
min.4 to max.100 % (dry mass)
min.31 to max.41 % water content

Ranges depend on connected measuring instrument

min.0 to max.80 digits
min.0,3 to max.42.2 wt.-%
min.0,3 to max.12 CM-%

Ranges depend on connected measuring instrument

Wood MoistureStructural Moisture
12 Measuring instruments compatible2 Usecases
M 20-OF 15
Needs a carrier system
min.4 to max.100 % (dry mass)
min.31 to max.41 % water content

Ranges depend on connected measuring instrument

min.0 to max.80 digits
min.0,3 to max.42.2 wt.-%
min.0,3 to max.12 CM-%

Ranges depend on connected measuring instrument

Structural Moisture
6 Measuring instruments compatible
M 6
min.0 to max.80 digits
min.0,3 to max.42.2 wt.-%
min.0,3 to max.12 CM-%

Ranges depend on connected measuring instrument

Structural Moisture
6 Measuring instruments compatible
M 6-150
Needs a carrier system
min.0 to max.80 digits
min.0,3 to max.42.2 wt.-%
min.0,3 to max.12 CM-%

Ranges depend on connected measuring instrument

Structural Moisture
6 Measuring instruments compatible
M 6-250
Needs a carrier system
min.0 to max.80 digits
min.0,3 to max.42.2 wt.-%
min.0,3 to max.12 CM-%

Ranges depend on connected measuring instrument

Structural Moisture
6 Measuring instruments compatible2 Usecases
M 6-Bi 200
Needs a carrier system
min.0 to max.80 digits
min.0,3 to max.42.2 wt.-%
min.0,3 to max.12 CM-%

Ranges depend on connected measuring instrument

Structural Moisture
6 Measuring instruments compatible2 Usecases
M 6-Bi 300
Needs a carrier system
min.0 to max.80 digits
min.0,3 to max.42.2 wt.-%
min.0,3 to max.12 CM-%

Ranges depend on connected measuring instrument

Structural Moisture
6 Measuring instruments compatible2 Usecases
M 20-Bi 200
Needs a carrier system
min.0 to max.80 digits
min.0,3 to max.42.2 wt.-%
min.0,3 to max.12 CM-%

Ranges depend on connected measuring instrument

Structural Moisture
6 Measuring instruments compatible2 Usecases
M 20-Bi 300
Needs a carrier system
min.0 to max.80 digits
min.0,3 to max.42.2 wt.-%
min.0,3 to max.12 CM-%

Ranges depend on connected measuring instrument

Structural Moisture
6 Measuring instruments compatible
M 21-100
min.0 to max.80 digits
min.0,3 to max.42.2 wt.-%
min.0,3 to max.12 CM-%

Ranges depend on connected measuring instrument

Structural Moisture
6 Measuring instruments compatible
M 21-250
min.0 to max.80 digits
min.0,3 to max.42.2 wt.-%
min.0,3 to max.12 CM-%

Ranges depend on connected measuring instrument

Structural Moisture
6 Measuring instruments compatible2 Usecases
M 25-100
min.0 to max.80 digits
min.0,3 to max.42.2 wt.-%
min.0,3 to max.12 CM-%

Ranges depend on connected measuring instrument

Structural Moisture
6 Measuring instruments compatible2 Usecases
M 25-300
min.0 to max.80 digits
min.0,3 to max.42.2 wt.-%
min.0,3 to max.12 CM-%

Ranges depend on connected measuring instrument

Structural Moisture
2 Measuring instruments compatible
Compact Bi 175
min.0.4 to max.6 wt.-%

Ranges depend on connected measuring instrument

Structural Moisture
2 Measuring instruments compatible
Compact HW 175
min.0.4 to max.6 wt.-%

Ranges depend on connected measuring instrument

Structural Moisture
4 Measuring instruments compatible2 Usecases
B 50
0 to 199 digits
0.3 to 8.5 wt.-%
0.3 to 6.5 CM-%
Structural Moisture
4 Measuring instruments compatible2 Usecases
B 60
0 to 199 digits
0.3 to 8.5 wt.-%
0.3 to 6.5 CM-%
Structural Moisture
4 Measuring instruments compatible
LB 71
0 to 199 digits
0.3 to 8.5 wt.-%
0.3 to 6.5 CM-%
Structural Moisture
3 Measuring instruments compatible2 Usecases
B 55 BL
0 to 199 digits
0.3 to 8.5 wt.-%
0.3 to 6.5 CM-%
Air HumidityAir TemperatureStructural Moisture
2 Measuring instruments compatible
RH-T 37 BL 160
0 to 100 % R.H.
±1.8 (10 to 90 % R.H.) Sensor Accuracy
-20 to 70 °C
±0.5 (-10 to 70 °C) Sensor Accuracy
Air HumidityAir TemperatureStructural Moisture
2 Measuring instruments compatible
RH-T 37 BL 320
0 to 100 % R.H.
±1.8 (10 to 90 % R.H.) Sensor Accuracy
-20 to 70 °C
±0.5 (-10 to 70 °C) Sensor Accuracy
Air HumidityAir TemperatureStructural Moisture
2 Measuring instruments compatible
RH-T 37 BL flex 250
0 to 100 % R.H.
±1.8 (10 to 90 % R.H.) Sensor Accuracy
-20 to 70 °C
±0.5 (-10 to 70 °C) Sensor Accuracy
Air HumidityAir TemperatureStructural Moisture
2 Measuring instruments compatible
RH-T 37 BL flex 350
0 to 100 % R.H.
±1.8 (10 to 90 % R.H.) Sensor Accuracy
-20 to 70 °C
±0.5 (-10 to 70 °C) Sensor Accuracy

Your question about our products