Air Humidity
Air Temperature
Structural Moisture

Humidity Probe
RH-T 37 BL 160

Ref.Nr. 31013140
Special probe for humidity and air temperature measurements.
DescriptionUsecases
DescriptionUsecases
RH-T 37 BL 160

Description

The RH-T 37 BL 160 is a probe for humidity und air temperature measurements - particularly suited for applications in bulk materials and solid materials (e.g. brickwork or screeds).
Its range of applications includes, among others, humidity analyses, damage survey, monitoring the drying of buildings, and checking whether floor or wall covers may be laid.

The probe pipe has a diameter of 5.5 mm which enables measurements in joints without having to accept damage to wall or floor tiles.

A Hydromette unit can be used to measure air humidity in a drill hole and sorption isotherms can be used to determine the moisture content of certain set building materials or whether coatings can be applied to these building materials.

In order to obtain very precise measurements the device should have an adaptation period of approx. 10 - 15 minutes to compensate temperature differences between the sensor and the surrounding climate.

Measuring ranges

Capacitive measuring
Capacitive measuring
Measuring ranges
0 to 100 % R.H.
±1.8 (10 to 90 % R.H.) Sensor Accuracy
Band Gap
Band Gap
Measuring ranges
-20 to 80 °C
±0.3 (0 to 60 °C) Sensor Accuracy

Specifications

  • Sensor pipe: 165 mm (length) and 5,5 mm (diameter)
  • Diaphragm filter for measuring in air containing dust, pollution, or high air flow velocity is standard equipment

Compatible instrumentsCan be used with these measuring instruments

32 Electrodes selectable
CH 17
4 to 100 % (dry mass)
0 to 200 digits
0.3 to 8.5 wt.-%
0.3 to 6.5 CM-%
0.3 to 25 wt.-%
0.3 to 12 CM-%
0 to 100 % R.H.
±1.8 (10 to 90 % R.H.) Sensor Accuracy
-20 to 80 °C
±0.3 (0 to 60 °C) Sensor Accuracy
-40 to 380 °C
±0.5 (0 to 60 °C) Sensor Accuracy
-50 to 250 °C
-30 to 170 °C
-2,5 to 2,5 m/s
12 Electrodes selectable
BL UNI 11
0 to 200 digits
0.1 to 11 wt.-%
0.1 to 10 CM-%
0 to 100 % R.H.
±1.8 (10 to 90 % R.H.) Sensor Accuracy
-20 to 80 °C
±0.3 (0 to 60 °C) Sensor Accuracy
-40 to 380 °C
±0.5 (0 to 60 °C) Sensor Accuracy
-50 to 250 °C
-50 to 350 °C

Accessories

Your question about this product

Stay informed about
GANN products & services